H2 Analyzer HY-OPTIMA 1700

ATEX Intrinsically Safe In-line Hydrogen Process Analyzer H2scan’s HY-OPTIMA? 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA? 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60oC. The HY-OPTIMA? 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

? Highly reliable

? Real time, continuous hydrogen measurement

? Low life cycle cost

? Tolerant of many harsh background contaminants

? Easy to install and operate

? No reference or carrier gases required

? Minimal maintenance required

? Non-consumable solid state technology

? No cross sensitivity to combustible gases

? Field-configurable settings


Feature

he HY-OPTIMA? 2700 Series inline hydrogen process analyzer is ideal for gas streams where real-time, 

hydrogen-specific measurements can enhance process plant efficiencies, improve yields, and reduce maintenance costs:


Refinery

?Catalytic reforming

?Hydrodesulphurization

?Fuel gas

?Tail gas treating units


Natural Gas

?H2 measurement in polymer feeds and flare gas process streams


Manufacturing

?Metals annealing

?Semiconductors

?Oil hydrogenation



Performance                                                                                                        



Operating Pressure at Analyzer:

Recommended:

0.95 1.1 atm absolute (14.0 16.1 psia)

Maximum:

2 atm absolute   (29.4 psia)

Note: Analyzers   are factory calibrated at 1 atm. For operation at higher pressure

special factory   calibration is required which may incur a nominal fee.

Process Gas Temperature:

-20 to 60°C

Flow Rate:


0.1 to 10 slpm

Operating Humidity:

< 95% RH   (non-condensing)

Calibration Interval:

90 days

Output Signals                                                                                                        



Analog: 4-20 mA


Serial: RS422

Relays: Optional IS barrier with two   programmable SPST relays

Power                                                                                                        



Input Voltage (Power Barrier)

Input Voltage   (Analyzer)

20 28 VDC, 24 VDC nominal

5 28 VDC, 10 VDC nominal

Input   Power: 10

W


Physical                                                                                                        



Dimensions


Weight

10.3in (L) x 3.4in (W) x 1.4in(D)

1.0 lbs (0.45 kg)

Adapter Fitting: ? in MNPT

Environmental                                                                                                        



Operating temp: -20 to 40°C

Storage temp:   -40 to 50°C


H2 analyzer